Guidelines and literature
Cardiovascular and Pulmonary
Cardiovascular
- 2015
Diagnostic performance of myocardial perfusion imaging with SPECT, CT and MR compared to fractional flow reserve as reference standard
Yang, Z., Zheng, H., Zhou, T., Yang, L. F., Hu, X. F., Peng, Z. H., . . . Sun, G. (2015). Diagnostic performance of myocardial perfusion imaging with SPECT, CT and MR compared to fractional flow reserve as reference standard. Int J Cardiol, 190, 103-105. doi:10.1016/j.ijcard.2015.04.091
- 2015
EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT (2015)
Verberne, H. J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., . . . Hesse, B. (2015). EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging, 42(12), 1929-1940. doi:10.1007/s00259-015-3139-x
- 2014
Prognostic value of normal stress myocardial perfusion imaging in diabetic patients: a meta-analysis.
Acampa, W., Cantoni, V., Green, R., Maio, F., Daniele, S., Nappi, C., . . . Cuocolo, A. (2014). Prognostic value of normal stress myocardial perfusion imaging in diabetic patients: a meta-analysis. J Nucl Cardiol, 21(5), 893-902; quiz 890-892, 903-895. doi:10.1007/s12350-014-9918-0
- 2014
SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: a meta analysis.
Zhou, T., Yang, L. F., Zhai, J. L., Li, J., Wang, Q. M., Zhang, R. J., . . . Sun, G. (2014). SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: a meta analysis. Eur J Radiol, 83(6), 951-956. doi:10.1016/j.ejrad.2014.02.018
- 2012
123I-MIBG myocardial scintigraphy for differentiating Parkinson's disease from other neurodegenerative parkinsonism: a systematic review and meta-analysis.
Orimo, S., Suzuki, M., Inaba, A., & Mizusawa, H. (2012). 123I-MIBG myocardial scintigraphy for differentiating Parkinson's disease from other neurodegenerative parkinsonism: a systematic review and meta-analysis. Parkinsonism Relat Disord, 18(5), 494-500. doi:10.1016/j.parkreldis.2012.01.009
- 2012
SNMMI/ASNC/SCCT Guideline for Cardiac SPECT/CT and PET/CT 1.0 (2012)
Dorbala, S., Ananthasubramaniam, K., Armstrong, I. S., Chareonthaitawee, P., DePuey, E. G., Einstein, A. J., . . . Wells, R. G. (2018). Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation. Journal of Nuclear Cardiology, 25(5), 1784-1846. Retrieved from https://doi.org/10.1007/s12350-018-1283-y. doi:10.1007/s12350-018-1283-y
- 2011
EANM/ESR/ECNC Hybrid cardiac imaging: SPECT/CT and PET/CT (2011)
Flotats, A., Knuuti, J., Gutberlet, M., Marcassa, C., Bengel, F. M., Kaufmann, P. A., . . . Hesse, B. (2011). Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine EANM, the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC). Eur J Nucl Med Mol Imaging, 38(1), 201-212. doi:10.1007/s00259-010-1586-y
- 2011
Meta-analysis of 123I-MIBG cardiac scintigraphy for the diagnosis of Lewy body-related disorders.
King, A. E., Mintz, J., & Royall, D. R. (2011). Meta-analysis of 123I-MIBG cardiac scintigraphy for the diagnosis of Lewy body-related disorders. Mov Disord, 26(7), 1218-1224. doi:10.1002/mds.23659
- 2008
EANM/ESC guidelines for radionuclide imaging of cardiac function (2008)
Hesse, B., Lindhardt, T. B., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bax, J. J., . . . Underwood, R. (2008). EANM/ESC guidelines for radionuclide imaging of cardiac function. Eur J Nucl Med Mol Imaging, 35(4), 851-885. doi:10.1007/s00259-007-0694-9
- 2008
SNM Myocardial Perfusion Imaging (2008)
Strauss, H. W., Miller, D. D., Wittry, M. D., Cerqueira, M. D., Garcia, E. V., Iskandrian, A. S., . . . Machac, J. (2008). Procedure guideline for myocardial perfusion imaging 3.3. J Nucl Med Technol, 36(3), 155-161. doi:10.2967/jnmt.108.056465
- 2007
ACC/AHA Guidelines on Perioperative Cardiovascular Evaluation and Care for Noncardiac Surgery(2007)
Fleisher, L. A., Beckman, J. A., Brown, K. A., Calkins, H., Chaikof, E. L., Fleischmann, K. E., . . . Yancy, C. W. (2007). ACC/AHA 2007 Guidelines on Perioperative Cardiovascular Evaluation and Care for Noncardiac Surgery: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 2002 Guidelines on Perioperative Cardiovascular Evaluation for Noncardiac Surgery) Developed in Collaboration With the American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Rhythm Society, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, and Society for Vascular Surgery. J Am Coll Cardiol, 50(17), 1707-1732. doi:10.1016/j.jacc.2007.09.001
- 2005
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology (2005)
myocardial perfusion imaging in nuclear cardiology
- 2002
SNM Gated Equilibrium Radionuclide Ventriculography (2002)
Scheiner, J., Sinusas, A., Wittry, M. D., Royal, H. D., Machac, J., Balon, H. R., & Lang, O. Society of Nuclear Medicine Procedure Guideline for Gated Equilibrium Radionuclide Ventriculography. Retrieved from https://s3.amazonaws.com/rdcms-snmmi/files/production/public/docs/Gated%...
Nuclear Cardiology
- 2021
Reduction of cardiac imaging tests during the COVID-19 pandemic: The case of Italy. Findings from the IAEA Non-invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID)
DONDI, M., et al., Reduction of cardiac imaging tests during the COVID-19 pandemic: The case of Italy. Findings from the IAEA Non-invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID), Int J Cardiol (2021)
- 2021
Impact of COVID-19 on Diagnostic Cardiac Procedural Volume in Oceania: The IAEA Non-Invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID)
O'SULLIVAN, P., et al., Impact of COVID-19 on Diagnostic Cardiac Procedural Volume in Oceania: The IAEA Non-Invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID), Heart Lung Circ 30 10 (2021) 1477-1486.
- 2021
Impact of COVID-19 on Cardiovascular Testing in the United States Versus the Rest of the World: The INCAPS-COVID Study
HIRSCHFELD, C.B., et al., Impact of COVID-19 on Cardiovascular Testing in the United States Versus the Rest of the World: The INCAPS-COVID Study, JACC Cardiovasc Imaging (2021)
- 2021
Impact of COVID-19 on the imaging diagnosis of cardiac disease in Europe
WILLIAMS, M.C., et al., Impact of COVID-19 on the imaging diagnosis of cardiac disease in Europe, Open Heart (2021) 2021.
- 2021
Impact of COVID-19 Pandemic on Cardiovascular Testing in Asia: The IAEA INCAPS-COVID Study
INTERNATIONAL ATOMIC ENERGY AGENCY, Training Curriculum for Nuclear Medicine Physicians IAEA, Vienna (2019)pp.
- 2021
Worldwide Diagnostic Reference Levels for Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging: Findings From INCAPS
HIRSCHFELD, C.B., et al., Worldwide Diagnostic Reference Levels for Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging: Findings From INCAPS, JACC Cardiovasc Imaging (2020)
- 2021
Programmes of the International Atomic Energy Agency for Nuclear Cardiology and Quality Management
DONDI, M., PAEZ, D., SURESHKUMAR, S., Programmes of the International Atomic Energy Agency for Nuclear Cardiology and Quality Management, Nuclear Cardiology Basic and Advanced Concepts in Clinical Practice, Springer International Publishing, (2021).
- ‹ previous
- 4 of 5
- next ›